Results 1 - 15 de 15
Filter
1.
Cell Rep Med ; 3(10): 100784, 2022 10 18.
Article in English | MEDLINE | ID: covidwho-2251643

ABSTRACT

Rapid antigen tests in the form of lateral flow devices (LFDs) allow testing of a large population for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). To reduce the variability in device interpretation, we show the design and testing of an artifical intelligence (AI) algorithm based on machine learning. The machine learning (ML) algorithm is trained on a combination of artificially hybridized LFDs and LFD data linked to quantitative real-time PCR results. Participants are recruited from assisted test sites (ATSs) and health care workers undertaking self-testing, and images are analyzed using the ML algorithm. A panel of trained clinicians is used to resolve discrepancies. In total, 115,316 images are returned. In the ATS substudy, sensitivity increased from 92.08% to 97.6% and specificity from 99.85% to 99.99%. In the self-read substudy, sensitivity increased from 16.00% to 100% and specificity from 99.15% to 99.40%. An ML-based classifier of LFD results outperforms human reads in assisted testing sites and self-reading.


Subject(s)
COVID-19 , Humans , COVID-19/diagnosis , SARS-CoV-2/genetics , Sensitivity and Specificity , COVID-19 Testing , Machine Learning
2.
Microbiol Spectr ; 10(5): e0246822, 2022 Oct 26.
Article in English | MEDLINE | ID: covidwho-2038254

ABSTRACT

Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) vaccine coverage remains incomplete, being only 15% in low-income countries. Rapid point-of-care tests predicting SARS-CoV-2 infection susceptibility in the unvaccinated may assist in risk management and vaccine prioritization. We conducted a prospective cohort study in 2,826 participants working in hospitals and Fire and Police services in England, UK, during the pandemic (ISRCTN5660922). Plasma taken at recruitment in June 2020 was tested using four lateral flow immunoassay (LFIA) devices and two laboratory immunoassays detecting antibodies against SARS-CoV-2 (UK Rapid Test Consortium's AbC-19 rapid test, OrientGene COVID IgG/IgM rapid test cassette, SureScreen COVID-19 rapid test cassette, and Biomerica COVID-19 IgG/IgM rapid test; Roche N and Euroimmun S laboratory assays). We monitored participants for microbiologically confirmed SARS-CoV-2 infection for 200 days. We estimated associations between test results at baseline and subsequent infection, using Poisson regression models adjusted for baseline demographic risk factors for SARS-CoV-2 exposure. Positive IgG results on each of the four LFIAs were associated with lower rates of subsequent infection with adjusted incidence rate ratios (aIRRs) of 0.00 (95% confidence interval, 0.00 to 0.01), 0.03 (0.02 to 0.05), 0.07 (0.05 to 0.10), and 0.09 (0.07 to 0.12), respectively. The protective association was strongest for AbC-19 and SureScreen. The aIRR for the laboratory Roche N antibody assay at the manufacturer-recommended threshold was similar to those of the two best performing LFIAs at 0.03 (0.01 to 0.10). Lateral flow devices measuring SARS-CoV-2 IgG predicted disease risk in unvaccinated individuals over a 200-day follow-up. The association of some LFIAs with subsequent infection was similar to laboratory immunoassays. IMPORTANCE Previous research has demonstrated an association between the detection of antibodies to SARS-CoV-2 following natural infection and protection from subsequent symptomatic SARS-CoV-2 infection. Lateral flow immunoassays (LFIAs) detecting anti-SARS-CoV-2 IgG are a cheap, readily deployed technology that has been used on a large scale in population screening programs, yet no studies have investigated whether LFIA results are associated with subsequent SARS-CoV-2 infection. In a prospective cohort study of 2,826 United Kingdom key workers, we found positivity in lateral flow test results had a strong negative association with subsequent SARS-CoV-2 infection within 200 days in an unvaccinated population. Positivity on more-specific but less-sensitive tests was associated with a markedly decreased rate of disease; protection associated with testing positive using more sensitive devices detecting lower levels of anti-SARS-CoV-2 IgG was more modest. Lateral flow tests with high specificity may have a role in estimation of SARS-CoV-2 disease risk in unvaccinated populations.


Subject(s)
COVID-19 , Humans , COVID-19/diagnosis , COVID-19/epidemiology , SARS-CoV-2 , Prospective Studies , Sensitivity and Specificity , Antibodies, Viral , Immunoassay/methods , Immunoglobulin G , Immunoglobulin M
3.
J Fungi (Basel) ; 8(7)2022 Jul 21.
Article in English | MEDLINE | ID: covidwho-1957370

ABSTRACT

Mucormycosis is a highly aggressive angio-invasive disease of humans caused by fungi in the zygomycete order, Mucorales. Though a number of different species can cause mucormycosis, the principal agent of the disease worldwide is Rhizopus arrhizus, which accounts for the majority of rhino-orbital-cerebral, pulmonary, and disseminated infections in immunocompromised individuals. It is also the main cause of life-threatening infections in patients with poorly controlled diabetes mellitus, and in corticosteroid-treated patients with SARS-CoV-2 infection, where it causes the newly described disease, COVID-19-associated mucormycosis (CAM). Diagnosis currently relies on non-specific CT, a lengthy and insensitive culture from invasive biopsy, and a time-consuming histopathology of tissue samples. At present, there are no rapid antigen tests for the disease that detect biomarkers of infection, and which allow point-of-care diagnosis. Here, we report the development of an IgG1 monoclonal antibody (mAb), KC9, which is specific to Rhizopus arrhizus var. arrhizus (syn. Rhizopus oryzae) and Rhizopus arrhizus var. delemar (Rhizopus delemar), and which binds to a 15 kDa extracellular polysaccharide (EPS) antigen secreted during hyphal growth of the pathogen. Using the mAb, we have developed a competitive lateral-flow device (LFD) that allows rapid (30 min) and sensitive (~50 ng/mL running buffer) detection of the EPS biomarker, and which is compatible with human serum (limit of detection of ~500 ng/mL) and bronchoalveolar lavage fluid (limit of detection of ~100 ng/mL). The LFD, therefore, provides a potential novel opportunity for the non-invasive detection of mucormycosis caused by Rhizopus arrhizus.

4.
BMC Public Health ; 22(1): 1373, 2022 07 18.
Article in English | MEDLINE | ID: covidwho-1938307

ABSTRACT

BACKGROUND: In July 2021, a randomised controlled trial was conducted to compare the effect on SARS-CoV-2 transmission of seven days of Daily Contact Testing (DCT) using Lateral Flow Test (LFT) and two Polymerase Chain Reaction (PCR) tests as an alternative to 10 days of standard self-isolation with one PCR, following close contact with a SARS-CoV-2 carrier. In this qualitative study, we used a nested process evaluation to aid interpretation of the trial and provide insight into factors influencing use of tests, understanding of test results, and how tests were used to inform behavioural decisions. METHODS: Interviews were conducted with 60 participants (42 randomised to DCT and 18 randomised to self-isolation) who had been in close contact with a confirmed SARS-CoV-2 carrier and had consented to take part in the trial. RESULTS: Data were organised into three overarching themes: (1) assessing the risks and benefits of DCT (2) use of testing during the study period and (3) future use of testing. Attitudes toward DCT as an alternative to self-isolation and behaviour during the testing period appeared to be informed by an assessment of the associated risks and benefits. Participants reported how important it was for them to avoid isolation, how necessary self-isolation was considered to be, and the ability of LFTs to detect infection. Behaviour during the testing period was modified to reduce risks and harms as much as possible. Testing was considered a potential compromise, reducing both risk of transmission and the negative impact of self-isolation, and was regarded as a way to return to normal. CONCLUSION: Participants in this study viewed DCT as a sensible, feasible, and welcome means of avoiding unnecessary self-isolation. Although negative LFTs provided reassurance, most people still restricted their activity as recommended. DCT was also highly valued by those in vulnerable households as a means of providing reassurance of the absence of infection and as an important means of detecting infection and prompting self-isolation when necessary.


Subject(s)
COVID-19 , SARS-CoV-2 , COVID-19/diagnosis , COVID-19/prevention & control , Humans , SARS-CoV-2/genetics
5.
Front Public Health ; 10: 863862, 2022.
Article in English | MEDLINE | ID: covidwho-1855468

ABSTRACT

The diagnostic protocol currently used globally to identify Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) infection is RT-qPCR. The spread of these infections and the epidemiological imperative to describe variation across the virus genome have highlighted the importance of sequencing. SARS-CoV-2 rapid antigen diagnostic tests (RADTs) are designed to detect viral nucleocapsid protein with positive results suggestive of the presence of replicating virus and potential infectivity. In this study, we developed a protocol for recovering SARS-CoV-2 RNA from "spent" RADT devices of sufficient quality that can be used directly for whole virus genome sequencing. The experimental protocol included the spiking of RADTs at different concentrations with viable SARS-CoV-2 variant Alpha (lineage B.1.1.7), lysis for direct use or storage. The lysed suspensions were used for RNA extraction and RT-qPCR. In parallel, we also tested the stability of the viral RNA in the RADTs and the RNA extracted from the RADTs was used as a template for tiling-PCR and whole virus genome sequencing. RNA recovered from RADTs spiked with SARS-CoV-2 was detected through RT-qPCR with Ct values suitable for sequencing and the recovery from RADTs was confirmed after 7 days of storage at both 4 and 20°C. The genomic sequences obtained at each time-point aligned to the strain used for the spiking, demonstrating that sufficient SARS-CoV-2 viral genome can be readily recovered from positive-RADT devices in which the virus has been safely inactivated and genomically conserved. This protocol was applied to obtain whole virus genome sequence from RADTs ran in the field where the omicron variant was detected. The study demonstrated that viral particles of SARS-CoV-2 suitable for whole virus genome sequencing can be recovered from positive spent RADTs, extending their diagnostic utility, as a risk management tool and for epidemiology studies. In large deployment of the RADTs, positive devices could be safely stored and used as a template for sequencing allowing the rapid identification of circulating variants and to trace the source and spread of outbreaks within communities and guaranteeing public health.


Subject(s)
COVID-19 , SARS-CoV-2 , COVID-19/diagnosis , Genome, Viral , Humans , RNA, Viral/genetics , SARS-CoV-2/genetics
6.
BMC Public Health ; 22(1): 742, 2022 04 13.
Article in English | MEDLINE | ID: covidwho-1789111

ABSTRACT

BACKGROUND: Daily testing using a rapid Lateral Flow Device (LFD) has been suggested as an alternative to self-isolation. A randomised trial comparing daily contact testing (DCT) in schools with self-isolation found that SARS-CoV-2 transmission within school was comparable and low in both groups. However, if this approach is to be adopted widely, it is critical that we understand the perspective of those who will be delivering and receiving DCT. The aim of this qualitative process study embedded in the randomised controlled trial (RCT) was to improve understanding of a range of behavioural factors that could influence implementation. METHODS: Interviews were conducted with 63 participants, including staff, students, and parents of students who had been identified as being in close contact with someone with COVID-19. The topic guide explored perceptions of daily testing, understanding of positive and negative test results, and adherence to guidance. Data were analysed using an inductive thematic approach. RESULTS: Results were organised under three main headings: (1) factors influencing daily testing (2) interpretation of test results (3) behaviour during testing period. Participants recognized that daily testing may allow students to remain in school, which was viewed as necessary for both education and social needs. Whilst some felt safer as a result of daily testing, others raised concerns about safety. Participants did not always understand how to interpret and respond to test results, and although participants reported high levels of adherence to the guidance, improved communications were desired. CONCLUSION: Daily testing may be a feasible and acceptable alternative to self-isolation among close contacts of people who test positive. However, improved communications are needed to ensure that all students and parents have a good understanding of the rationale for testing, what test results mean, how test results should be acted on, and how likely students are to test positive following close contact. Support is needed for students and parents of students who have to self-isolate and for those who have concerns about the safety of daily testing.


Subject(s)
COVID-19 , COVID-19 Testing , Feasibility Studies , Humans , SARS-CoV-2 , Schools
7.
BMC Public Health ; 22(1): 588, 2022 03 25.
Article in English | MEDLINE | ID: covidwho-1759733

ABSTRACT

BACKGROUND: Antigen testing using lateral flow devices (LFDs) plays an important role in the management of the novel coronavirus pandemic of 2019 (COVID-19) by rapidly identifying individuals who are asymptomatically carrying high levels of the virus. By January 2021, LFD community testing sites were set up across English local authority areas to support the management and containment of regional COVID-19 cases, initially targeting essential workers unable to work from home during the national lockdown. This study aimed to examine the characteristics and motivations of individuals accessing community LFD testing across two local authority areas (LAAs) in the South West of England. METHODS: Data were collected as part of a service evaluation from December 22nd 2020 until March 15th 2021 for two LAAs. Demographic and postcode data were collected from an online test appointment booking platform and the National Health Service testing service online system, with data accessed from Public Health England. An online survey was sent to individuals who made a testing appointment at an LAA1 site using the online booking platform, consisting of 12 questions to collect data on individual's motivations for and experiences of testing. RESULTS: Data were available for individuals who completed 12,516 tests in LAA1 and 12,327 tests in LAA2. Most individuals who engaged with testing were female, working age, white, and worked as early years or education staff, health and social care staff, and supermarket or food production staff. 1249 individuals completed the survey with 60% of respondents reported getting tested for work-related reasons. Individuals first heard about LFD testing through various channels including work, media, and word of mouth, and decided to get tested based on the ease and convenience of testing, workplace communications, and to identify asymptomatic cases to help stop the spread. Most tests were completed by individuals living in less deprived areas based on national deciles of deprivation. CONCLUSIONS: While national and local COVID-19 testing strategies have evolved, community and personal LFD testing remains a crucial pillar of the testing strategy. Future studies should collect quantitative and qualitative data from residents to most effectively shape testing offers based on the needs and preferences of their population.


Subject(s)
COVID-19 , Motivation , COVID-19/diagnosis , COVID-19/epidemiology , COVID-19 Testing , Communicable Disease Control , Female , Humans , State Medicine
8.
Clin Infect Dis ; 74(3): 407-415, 2022 02 11.
Article in English | MEDLINE | ID: covidwho-1684538

ABSTRACT

BACKGROUND: How severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infectivity varies with viral load is incompletely understood. Whether rapid point-of-care antigen lateral flow devices (LFDs) detect most potential transmission sources despite imperfect clinical sensitivity is unknown. METHODS: We combined SARS-CoV-2 testing and contact tracing data from England between 1 September 2020 and 28 February 2021. We used multivariable logistic regression to investigate relationships between polymerase chain reaction (PCR)-confirmed infection in contacts of community-diagnosed cases and index case viral load, S gene target failure (proxy for B.1.1.7 infection), demographics, SARS-CoV-2 incidence, social deprivation, and contact event type. We used LFD performance to simulate the proportion of cases with a PCR-positive contact expected to be detected using 1 of 4 LFDs. RESULTS: In total, 231 498/2 474 066 (9%) contacts of 1 064 004 index cases tested PCR-positive. PCR-positive results in contacts independently increased with higher case viral loads (lower cycle threshold [Ct] values), for example, 11.7% (95% confidence interval [CI] 11.5-12.0%) at Ct = 15 and 4.5% (95% CI 4.4-4.6%) at Ct = 30. B.1.1.7 infection increased PCR-positive results by ~50%, (eg, 1.55-fold, 95% CI 1.49-1.61, at Ct = 20). PCR-positive results were most common in household contacts (at Ct = 20.1, 8.7% [95% CI 8.6-8.9%]), followed by household visitors (7.1% [95% CI 6.8-7.3%]), contacts at events/activities (5.2% [95% CI 4.9-5.4%]), work/education (4.6% [95% CI 4.4-4.8%]), and least common after outdoor contact (2.9% [95% CI 2.3-3.8%]). Contacts of children were the least likely to test positive, particularly following contact outdoors or at work/education. The most and least sensitive LFDs would detect 89.5% (95% CI 89.4-89.6%) and 83.0% (95% CI 82.8-83.1%) of cases with PCR-positive contacts, respectively. CONCLUSIONS: SARS-CoV-2 infectivity varies by case viral load, contact event type, and age. Those with high viral loads are the most infectious. B.1.1.7 increased transmission by ~50%. The best performing LFDs detect most infectious cases.


Subject(s)
COVID-19 , SARS-CoV-2 , COVID-19 Testing , Child , Family Characteristics , Humans , Viral Load
9.
J Clin Epidemiol ; 145: 14-19, 2022 05.
Article in English | MEDLINE | ID: covidwho-1683271

ABSTRACT

OBJECTIVE: This paper motivates and justifies the use of antigen tests for epidemic control as distinct from a diagnostic test. STUDY DESIGN AND SETTING: We discuss the relative advantages of antigen and PCR tests, summarizing evidence from both the literature as well as Austrian schools, which conducted frequent, mass rapid antigen testing during the spring of 2021. While our report on testing predates Delta, we have updated the review with recent data on viral loads in breakthrough infections and more information about testing efficacy, especially in children. RESULTS: Rapid antigen tests detect proteins at the surface of virus particles, identifying the disease during its infectious phase. In contrast, PCR tests detect viral genomes: they can thus diagnose COVID-19 before the infectious phase but also react to remnants of the virus genome, even weeks after live virus ceases to be detectable in the respiratory tract. Furthermore, the logistics for administering the tests are different. Large-scale rapid antigen testing in Austrian schools showed low false-positive rates along with an approximately 10% lower effective reproduction number in the tested cohort. CONCLUSION: Using antigen tests at least 2-3 times per week could become a powerful tool to suppress the COVID-19 pandemic.


Subject(s)
COVID-19 , SARS-CoV-2 , Austria/epidemiology , COVID-19/diagnosis , COVID-19/epidemiology , Child , Humans , Pandemics , Schools , Sensitivity and Specificity
10.
Front Public Health ; 9: 714041, 2021.
Article in English | MEDLINE | ID: covidwho-1367764

ABSTRACT

Introduction: In December 2020 and January 2021 Public Health England (PHE) with NHS Test and Trace conducted a study to explore the feasibility and acceptability of daily testing as an alternative to self-isolation following close contact with a confirmed COVID-19 case. This qualitative paper aims to identify factors influencing uptake among those offered daily testing, and the subsequent impact on behaviour. Methods: We conducted in-depth interviews with 52 participants who had taken part in the feasibility study. Participants were asked about their experiences of daily testing or self-isolating, their reasons for choosing to test or isolate, and their behaviour during the study period. Data were analysed using inductive thematic analysis. Results: Results are presented under two main headings: (1) factors influencing acceptance of testing and (2) impact of test results. Participants appeared highly motivated to engage in behaviours that would protect others from the virus. Factors influencing the decision to accept testing included (1) needing to avoid self-isolation, (2) concerns about test sensitivity, and (3) perceived benefits of detecting infection. Participants who were taking tests reported: (1) positive consequences following confirmation of COVID status, (2) engaging in essential activities, (3) uncertainty, and (4) self-isolating whilst testing. Conclusions: This study has identified a range of factors that appear to influence the decision to engage in daily testing or to self-isolate following close contact with a positive case, many of which could be addressed by clear communications. Covid-19 infection rates and government restrictions influenced experiences, and so further research is needed to explore perceptions of daily testing and behaviour following close contact with a positive case among a wider range of individuals, in the context of lower rates of COVID-19, few government restrictions on general population behaviour and more widespread testing.


Subject(s)
COVID-19 Testing/methods , COVID-19 , Contact Tracing , Quarantine , COVID-19/diagnosis , England , Humans
11.
BMC Infect Dis ; 21(1): 828, 2021 Aug 18.
Article in English | MEDLINE | ID: covidwho-1365326

ABSTRACT

BACKGROUND: Lateral flow devices (LFDs) are viral antigen tests for the detection of SARS-CoV-2 that produce a rapid result, are inexpensive and easy to operate. They have been advocated for use by the World Health Organisation to help control outbreaks and break the chain of transmission of COVID-19 infections. There are now several studies assessing their accuracy but as yet no systematic review. Our aims were to assess the sensitivity and specificity of LFDs in a systematic review and summarise the sensitivity and specificity of these tests. METHODS: A targeted search of Pubmed and Medxriv, using PRISMA principles, was conducted identifying clinical studies assessing the sensitivity and specificity of LFDs as their primary outcome compared to reverse transcriptase polymerase chain reaction (RT-PCR) for the detection of SARS-CoV-2. Based on extracted data sensitivity and specificity was calculated for each study. Data was pooled based on manufacturer of LFD and split based on operator (self-swab or by trained professional) and sensitivity and specificity data were calculated. RESULTS: Twenty-four papers were identified involving over 26,000 test results. Sensitivity from individual studies ranged from 37.7% (95% CI 30.6-45.5) to 99.2% (95% CI 95.5-99.9) and specificity from 92.4% (95% CI 87.5-95.5) to 100.0% (95% CI 99.7-100.0). Operation of the test by a trained professional or by the test subject with self-swabbing produced comparable results. CONCLUSIONS: This systematic review identified that the performance of lateral flow devices is heterogeneous and dependent on the manufacturer. Some perform with high specificity but a great range of sensitivities were shown (38.32-99.19%). Test performance does not appear dependent on the operator. Potentially, LFDs could support the scaling up of mass testing to aid track and trace methodology and break the chain of transmission of COVID-19 with the additional benefit of providing individuals with the results in a much shorter time frame.


Subject(s)
COVID-19 Testing/standards , COVID-19/diagnosis , SARS-CoV-2/isolation & purification , Antigens, Viral/analysis , COVID-19/epidemiology , False Negative Reactions , False Positive Reactions , Female , Humans , Male , Pandemics , RNA, Viral/genetics , Reverse Transcriptase Polymerase Chain Reaction , SARS-CoV-2/genetics , SARS-CoV-2/immunology , Sensitivity and Specificity
12.
ACS Appl Mater Interfaces ; 13(22): 25694-25700, 2021 Jun 09.
Article in English | MEDLINE | ID: covidwho-1246315

ABSTRACT

Containing the global severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) pandemic has been an unprecedented challenge due to high horizontal transmissivity and asymptomatic carriage rates. Lateral flow device (LFD) immunoassays were introduced in late 2020 to detect SARS-CoV-2 infection in asymptomatic or presymptomatic individuals rapidly. While LFD technologies have been used for over 60 years, their widespread use as a public health tool during a pandemic is unprecedented. By the end of 2020, data from studies into the efficacy of the LFDs emerged and showed these point-of-care devices to have very high specificity (ability to identify true negatives) but inadequate sensitivity with high false-negative rates. The low sensitivity (<50%) shown in several studies is a critical public health concern, as asymptomatic or presymptomatic carriers may wrongly be assumed to be noninfectious, posing a significant risk of further spread in the community. Here, we show that the direct visual readout of SARS-CoV-2 LFDs is an inadequate approach to discriminate a potentially infective viral concentration in a biosample. We quantified significant immobilized antigen-antibody-labeled conjugate complexes within the LFDs visually scored as negative using high-sensitivity synchrotron X-ray fluorescence imaging. Correlating quantitative X-ray fluorescence measurements and quantitative reverse transcription-polymerase chain reaction (qRT-PCR) determined numbers of viral copies, we identified that negatively scored samples could contain up to 100 PFU (equivalent here to ∼10 000 RNA copies/test). The study demonstrates where the shortcomings arise in many of the current direct-readout SARS-CoV-2 LFDs, namely, being a deficiency in the readout as opposed to the potential level of detection of the test, which is orders of magnitude higher. The present findings are of importance both to public health monitoring during the Coronavirus Disease 2019 (COVID-19) pandemic and to the rapid refinement of these tools for immediate and future applications.


Subject(s)
COVID-19/diagnosis , COVID-19/virology , Immunoassay/instrumentation , Severe acute respiratory syndrome-related coronavirus/isolation & purification , Animals , Chlorocebus aethiops , Microscopy, Electron, Transmission , Real-Time Polymerase Chain Reaction , Reference Standards , Severe acute respiratory syndrome-related coronavirus/ultrastructure , Sensitivity and Specificity , Spectrometry, X-Ray Emission , Vero Cells
13.
Mycoses ; 64(9): 1002-1014, 2021 Sep.
Article in English | MEDLINE | ID: covidwho-1148083

ABSTRACT

Invasive aspergillosis (IA) is an increasingly recognised phenomenon in critically ill patients in the intensive care unit, including in patients with severe influenza and severe coronavirus disease 2019 (COVID-19) infection. To date, there are no consensus criteria on how to define IA in the ICU population, although several criteria are used, including the AspICU criteria and new consensus criteria to categorise COVID-19-associated pulmonary aspergillosis (CAPA). In this review, we describe the epidemiology of IA in critically ill patients, most common definitions used to define IA in this population, and most common clinical specimens obtained for establishing a mycological diagnosis of IA in the critically ill. We also review the most common diagnostic tests used to diagnose IA in this population, and lastly discuss the most common clinical presentation and imaging findings of IA in the critically ill and discuss areas of further needed investigation.


Subject(s)
Aspergillus/genetics , COVID-19/complications , Diagnostic Techniques and Procedures/standards , Intensive Care Units/standards , Invasive Pulmonary Aspergillosis/classification , Invasive Pulmonary Aspergillosis/diagnosis , Practice Guidelines as Topic , Adult , Aged , Aged, 80 and over , Aspergillus/isolation & purification , COVID-19/microbiology , Critical Illness/classification , Female , Humans , Invasive Pulmonary Aspergillosis/physiopathology , Male , Mannans/blood , Middle Aged , Polymerase Chain Reaction , SARS-CoV-2
14.
J Fungi (Basel) ; 7(1)2020 Dec 31.
Article in English | MEDLINE | ID: covidwho-1011569

ABSTRACT

Invasive pulmonary aspergillosis (IPA) caused by Aspergillus fumigatus is a life-threatening lung disease of immunocompromised patients. Diagnosis currently relies on non-specific chest CT, culture of the fungus from invasive lung biopsy, and detection of the cell wall carbohydrate galactomannan (GM) in serum or in BAL fluids recovered during invasive bronchoscopy. Urine provides an ideal bodily fluid for the non-invasive detection of pathogen biomarkers, with current urine-based immunodiagnostics for IPA focused on GM. Surrogate protein biomarkers might serve to improve disease detection. Here, we report the development of a monoclonal antibody (mAb), PD7, which is specific to A. fumigatus and related species in the section Fumigati, and which binds to its 18 kDa ribotoxin Asp f I. Using PD7, we show that the protein is secreted during hyphal development, and so represents an ideal candidate for detecting invasive growth. We have developed a lateral-flow device (Afu-LFD®) incorporating the mAb which has a limit of detection of ~15 ng Asp f I/mL urine. Preliminary evidence of the test's diagnostic potential is demonstrated with urine from a patient with acute lymphoid leukaemia with probable IPA. The Afu-LFD® therefore provides a potential novel opportunity for non-invasive urine-based detection of IPA caused by A. fumigatus.

15.
Clin Oncol (R Coll Radiol) ; 33(1): e73-e81, 2021 01.
Article in English | MEDLINE | ID: covidwho-856571

ABSTRACT

The coronavirus disease 2019 (COVID-19) pandemic due to infection by a new human coronavirus, severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), has seriously disrupted the provision of oncology services and their uptake. Antibody testing, both at an individual level and of populations, has been widely viewed to be a key activity for guiding the options for treatment of high-risk individuals, as well as the implementation of safe control of infection measures. Ideally, the detection of a specific antibody should signify that all individuals tested have been infected by SARS-CoV-2 and that in the case of specific IgG that they are immune to further infection. This would enable SARS-CoV-2-infected individuals to be appropriately managed and healthcare workers shown to be immune to return to work where they would no longer pose a risk to their patients or be at risk themselves. Unfortunately, this is not the case for COVID-19, where it has been shown that immunity may not be protective, and seroconversion delayed or absent. The variability in antibody test performance, particularly that of lateral flow assays, has caused confusion for the public and healthcare professions alike. Many antibody test devices have been made available without independent evaluations and these may lack both adequate sensitivity and specificity. This review seeks to educate healthcare workers, particularly those working in oncology, of the current benefits and limitations of SARS-CoV-2 antibody testing.


Subject(s)
COVID-19 Serological Testing/methods , COVID-19 Serological Testing/standards , COVID-19/immunology , Immunoassay/standards , Oncologists , Humans , Immunoassay/methods , Male , Occupational Health/standards , SARS-CoV-2/immunology , Sensitivity and Specificity
SELECTION OF CITATIONS